X-ray fluorescence (XRF) spectrometers are designed to detect the elemental composition of various materials. These powerful analytical instruments play a key role in scientific research, quality control, and industrial applications.
Sample preparation is an essential link in the XRF analytical chain. High-quality sample preparation is critical for performing accurate chemical analysis with XRF. Whether the samples are loose or pressed powders, fused beads, solid samples, or liquids, finding the right approach to sample preparation is the first step in achieving accurate and reproducible results.
Fusion is an advanced method of sample preparation. It involves dissolving a fully oxidized sample at high temperatures in a suitable solvent (flux) in a platinum, zirconium, or graphite crucible. The molten mixture is stirred and poured into molds to cool, forming glass disks for XRF analysis. It can also be poured into a beaker to create a solution for AA or ICP analysis.
TY Induction's Fusion Instrument is a high-frequency induction heating technology-based laboratory device that can prepare glass disk samples for XRF analysis, as well as borate and peroxide solutions for ICP and AA analysis.
Our Induction Fusion Machine can help you obtain better XRF analytical results in your laboratory. Recognized by customers for its fast and excellent homogenization of melt, its uniform heating leads to highly reproducible results. Additionally, all its fusion parameters can be modified to achieve the desired fusion conditions, ensuring precise and reliable sample preparation.
Choose Tianyuan as your partner in XRF analysis sample preparation, and experience the benefits of advanced fusion technology for superior analytical outcomes.
Photos
Benefits of Induction Fusion Sample Preparation
l Advanced Heating Technology: IGBT based Induction Heating technology
l Rapid Heating: In just 30 seconds, the material can be heated from room temperature to 1200°C.
l Precise Temperature Control: Each fusion position is equipped with independent induction heater and coil. For example, the TY-8MC model has four (4) induction heaters & coils for fusion heating and two (2) induction heaters & coils for molding heating.
l High Productivity: Automated design can process multiple samples in batches, improving overall efficiency. 10 minutes per cycle, up to 20 samples can be prepared per hour
l Low Maintenance Cost: no costly spare parts
1.Molds and Crucibles holders are made of superior quality temperature-resistant alloy to ensure a service life of up to 10 years.
2.TY Induction offers pure titanium tongs to replace platinum-coated pliers. A pair of tongs can be used for more than decades, saving the re-platinum-coated repair cost of platinum-coated tongs.
l High Performance: During the fusion process, the molten mixture is always agitated horizontally and centrifugally to ensure that materials are fully mixed and guarantee the homogeneity of samples.
l Enhanced Security: Closed working chamber avoids the risk of open flames (gas heating) or high temperature radiation, while the automatic casting design eliminates contact with hot materials and surfaces for enhanced safety and really cold-to-cold operation.
l Easy to Operate (PLC control): TY Induction's Induction Fusion Sample Preparation Machine has a one-touch operation feature and a wide range of predefined fusion 15 programs that avoids deviation or contamination caused by manual operation and ensure sample preparation standardization.
l Environmental Protection: Built-in exhaust system removes waste gas.
l A wide range of models to choose from:
TY-2MC: 1 fusion +1 molding (manual casting)
TY-2AC: 1 fusion +1 molding (auto casting)
TY-4MC: 2 fusion +2 molding (manual casting)
TY-4AC: 2 fusion +2 molding (auto casting)
TY-8MC: 4 fusion +4 molding (manual casting)
TY-8AC: 4 fusion +4 molding (auto casting)
TY-4MFA: 2 fusion +2 molding (auto casting); Simply touch a button on panel to select sample preparation for XRF, ICP or AA analysis
TY-NFM: Specially designed for sample preparation for XRF spectrometer and direct reading spectrometer, especially for sample preparation of non- ferrous metals such as copper, aluminum and zinc
TY-MRM: Metal Sample Preparation Machine (centrifugal casting)
Read More
Secification
Power Input | Single AC220V/50HZ | ADJ. Heating Time | 0s~999s |
Voltage | AC180~AC240V | ADJ. molding Time | 0s~999s |
Max. Power | 4kw (single station)6kw (two or more stations) | Vibration Time | 0s~999s |
Oscillating Frequency | 60~100KHz | Max. Tempt. | 1500℃ |
Vibration Frequency | 1 t/min-37t/min | Spinning Speed | 30 r/min-34 r/min |
Fusion Current | 110~500A | Molding Current | 120~600A |
Video
Similar Cases
Features
Features of our Induction Fusion Instrument
High frequency Induction heating technology base
Rapid heating: from room temperature to 1000 degrees in 30 seconds
High sample throughput of 100 samples more per day 8 hours
Easy operation: controlled by PLC with Touch panel HMI
Precise temperature controlling ensures quality of samples
15 user-definable recipes can be saved
Separated fusion and molding design extends service life of Pt/Au crucible
Low energy consumption: only heat the crucible, heat the mold before casting
Environment friendly: Built-in exhaust system
Good working condition: reduced heat radiation